首页 / 产品 / ELISA试剂盒 / 人ELISA试剂盒
产品描述:人缺血修饰白蛋白(IMA)酶联免疫试剂盒为双抗夹心法ELISA试剂盒,定量检测血清、血浆、组织匀浆样本中的IMA含量。人缺血修饰白蛋白(IMA)是一种在组织缺血时形成的蛋白质,其形成机制涉及白蛋白与金属离子结合能力的改变。IMA在心血管疾病中具有诊断价值,如心肌缺血和肺栓塞的诊断,其检测有助于降低漏诊率,辅助评估患者预后。试剂盒检测范围为3.12 IU/mL-200 IU/mL,适用于心血管疾病动物模型研究、缺血再灌注损伤机制探索、药物干预效果评估等科研场景本品仅用于科研,不用于临床诊断,产品具体参数及操作步骤详见产品说明书。
缩写:IMA
种属:Homo sapiens (Human)
样本类型:serum, plasma, tissue homogenates
检测范围:3.12 IU/mL-200 IU/mL
灵敏度:0.78 IU/mL
反应时间:1-5h
样本体积:50-100ul
检测波长:450 nm
研究领域:Others
测定原理:quantitative
测定方法:Sandwich
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<10% | ||||||
Three samples of known concentration were tested in twenty assays to assess. | ||||||
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human IMA in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
Sample | Serum(n=4) | |||||
1:1 | Average % | 86 | ||||
Range % | 80-90 | |||||
1:2 | Average % | 99 | ||||
Range % | 95-102 | |||||
1:4 | Average % | 103 | ||||
Range % | 98-107 | |||||
1:8 | Average % | 94 | ||||
Range % | 88-98 |
回收率:
The recovery of human IMA spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
Sample Type | Average % Recovery | Range | ||||
Serum (n=5) | 95 | 90-98 | ||||
EDTA plasma (n=4) | 96 | 91-99 | ||||
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | ||||||
IU/mlOD1OD2AverageCorrected2002.4972.4672.4822.3631002.0131.9731.9931.874501.3001.2881.2941.175250.6870.7050.6960.57712.50.4420.4530.4480.3296.250.2830.3060.2950.1763.120.1980.2100.2040.08500.1210.1170.119 |
本试剂盒所含材料:
A micro ELISA plate ---The 96-well plate has been pre-coated with an anti-Human IMA antibody.
Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve.
One vial Biotin-labeled IMA antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody.
One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic.
One vial Biotin-antibody Diluent (15 ml/bottle) ---Dilute the Biotin-antibody.
One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution.
本试剂盒不含材料:
A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
An incubator can provide stable incubation conditions up to 37°C±5°
Centrifuge
Vortex
Squirt bottle, manifold dispenser, or automated microplate washer
Absorbent paper for blotting the microtiter plate
货期:3-5 working days
×