首页 / 产品 / ELISA试剂盒 / 大鼠ELISA试剂盒

Rat coagulation factor Ⅹ,FⅩ ELISA Kit

  • 中文名: 大鼠凝血因子Ⅹ(FⅩ)ELISA Kit
货号: IPD-E08441r
Price: ¥2500
数量:
大包装询价

产品详情

  • 产品描述:
    大鼠凝血因子Ⅹ(FⅩ)酶联免疫试剂盒为双抗夹心法ELISA试剂盒,定量检测血清、血浆样本中的F10含量。F10即凝血因子Ⅹ,在凝血级联反应中至关重要。其可被内、外源凝血途径激活为F10a,F10a与FVa等结合形成凝血酶原酶复合物,促使凝血酶原转化为凝血酶,最终使纤维蛋白原变成纤维蛋白,形成血栓,众多抗凝药以其为靶点展开研究。试剂盒检测范围为1.56 ng/mL-100 ng/mL,适用于凝血机制基础研究、抗凝药物开发评估以及血栓性疾病动物模型中凝血功能变化的动态监测,例如深静脉血栓、弥散性血管内凝血等病理过程的机制探索,也可用于肝功能障碍或维生素K缺乏相关模型中凝血因子合成能力的研究本品仅用于科研,不用于临床诊断,产品具体参数及操作步骤详见产品说明书。
  • 别名:
    F10Coagulation factor X ELISA Kit; EC 3.4.21.6 ELISA Kit; Stuart factor) [Cleaved into: Factor X light chain; Factor X heavy chain; Activated factor Xa heavy chain] ELISA Kit
  • 缩写:
    F10
  • Uniprot No.:
    Q63207
  • 种属:
    Rattus norvegicus (Rat)
  • 样本类型:
    serum, plasma
  • 检测范围:
    1.56 ng/mL-100 ng/mL
  • 灵敏度:
    0.39 ng/mL
  • 反应时间:
    1-5h
  • 样本体积:
    50-100ul
  • 检测波长:
    450 nm
  • 研究领域:
    Blood Coagulation
  • 测定原理:
    quantitative
  • 测定方法:
    Sandwich
  • 精密度:

    Intra-assay Precision (Precision within an assay): CV%<8%




    Three samples of known concentration were tested twenty times on one plate to assess.


    Inter-assay Precision (Precision between assays): CV%<10%




    Three samples of known concentration were tested in twenty assays to assess.



  • 线性度:

    To assess the linearity of the assay, samples were spiked with high concentrations of rat FⅩ in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.


    Sample

    Serum(n=4)


    1:1000

    Average %

    97


    Range %

    95-102


    1:2000

    Average %

    98


    Range %

    91-105


    1:4000

    Average %

    106


    Range %

    102-109


    1:8000

    Average %

    92


    Range %

    86-98


  • 回收率:

    The recovery of rat FⅩ spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.

    Sample Type

    Average % Recovery

    Range


    Serum (n=5)

    95

    89-98


    EDTA plasma (n=4)

    96

    92-100


  • 标准曲线:

    These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.







    ng/ml

    OD1

    OD2

    Average

    Corrected


    100

    1.959

    1.914

    1.936

    1.785


    50

    1.679

    1.657

    1.668

    1.517


    25

    1.300

    1.338

    1.319

    1.168


    12.5

    0.993

    0.969

    0.981

    0.830


    6.25

    0.678

    0.651

    0.664

    0.513


    3.12

    0.457

    0.443

    0.450

    0.299


    1.56

    0.377

    0.384

    0.380

    0.229


    0

    0.148

    0.155

    0.151




  • 货期:
    3-5 working days

客户数据及评论

折叠内容

大包装询价

×