首页 / 产品 / ELISA试剂盒 / 人ELISA试剂盒
Intra-assay Precision (Precision within an assay): CV%<15% | |||||||||
Three samples of known concentration were tested twenty times on one plate to assess. | |||||||||
Inter-assay Precision (Precision between assays): CV%<15% | |||||||||
Three samples of known concentration were tested in twenty assays to assess. |
Test parameter | specification | test result | |||||
Positive control | ≥0.8 | 2.078 | |||||
Negative control | ≤0.1 | 0.075 | |||||
Positive rate | 10,Positive | 100% | |||||
Negative rate | 10,Negative | 100% |
A 96-well Assay plate --The 96-well plate has been pre-coated with CCP antigen.
Negative Control (1 x 0.8 ml)
Positive Control (1 x 0.8 ml)
HRP-conjugated IgG antibody(1 x 10m)l --Bind to the human anti-CCP antibody, and HRP catalyzes the TMB to elicit a chromogenic reaction.
Sample Diluent (2 x 20 ml) --Dilute the sample to an appropriate concentration.
Wash Buffer (25x concentrate) (1 x 20 ml) --Wash away unbound or free substances.
A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 600 nm - 630 nm.
An incubator that can provide stable incubation conditions up to 37°C±5°C.
Centrifuge
Vortex
Squirt bottle, manifold dispenser, or automated microplate washer
Absorbent paper for blotting the microtiter plate
×